Brand Technology Linkage Qingfeng Variable Frequency Magnetic Levitation Chiller Create Energy Saving Pioneer

[China Aluminum Industry Network] Qingfeng has experienced more than ten years of development, and has created the Qingfeng brand, which is known for its high efficiency and reliability. After research and development and user comparison of data, it verified the energy efficiency of Qingfeng variable frequency magnetic levitation chiller.

品牌技术联动 青风变频磁悬浮冷水机打造节能先锋

First, the main features of Qingfeng Maglev frequency conversion chiller:

品牌技术联动 青风变频磁悬浮冷水机打造节能先锋



 Frequency conversion: The compressor has a built-in frequency converter, which can realize accurate temperature control over a wide range. The impact of the frequency conversion soft-start grid is reduced by 90%, and the low startup current is 2A, which increases the service life of the motor. Unit frequency: 0 ~ 800HZ higher speed: 48000 rev / min.

 Magnetic levitation: Using magnetic levitation technology, the mechanical movement is non-contact and the mechanical loss is reduced to zero.

 No oil: The compressor does not need lubricating oil, and the whole refrigeration system has no lubricating oil, and the heat exchange performance of the heat exchanger is improved by 10%. There is no need to change the lubricant when servicing the equipment.

 Efficient: The COP of the unit is up to 7.5kw/kw and IPLV: 13.0kw/kw. When the water temperature is 20°C, the unit is still safe to operate. The higher energy efficiency COP is 36.86kw/kw.

Safety: The unit has complete protection functions, and all the operating parameters of the compressor can be displayed digitally

Environmental protection: The refrigerant adopts R134a refrigerant with ODP of 0. Non-flammable, non-explosive, non-toxic, non-irritating, non-corrosive, non-chlorinated, no damage to the ozone layer.

 Low noise: The unit runs smoothly, and the noise of inorganic motion reduces the noise by 10%.

 Remote control: As long as there is a network, you can view the operating status of the unit, automatically pre-alarm, send alarm information.

Second, the main parameters

Cooling capacity: 530~2100kw/h

Larger operating power: 100 to 400kw/h

Operating frequency: 0 ~ 800HZ

Speed: 0-48,000 rpm.

Third, the unit schematic:

品牌技术联动 青风变频磁悬浮冷水机打造节能先锋

Fourth, the main configuration of the unit

Part Name

model

Brands

Brand origin

Magnetic levitation compressor

/

Danfoss (TURBOCOR)

United States

Inverter

/

Danfoss

United States

Magnetic suspension bearings

/

Danfoss

United States

Electronic expansion valve

/

Danfoss

United States

Refrigerant

R134a

DuPont

United States

Pressure Sensor

/

EMERSON/KF

United States/Zhejiang

Drying filter

/

EMERSON

United States

Temperature Sensor

/

EMERSON

United States

Sight glass

/

EMERSON

United States

Computer Control/PLC

S7-200

SIEMENS

Germany

touch screen

10-inch color screen

SIEMENS

Germany

Reactor

/

Jingxin

Shanghai

Safety valve

/

Dong Zi

Shanghai

Flow switch

/

KF

Zhejiang

Condenser

/

KF

Zhejiang

Evaporator

/

KF

Zhejiang

V. Economic Benefits

Magnetic suspension centrifugal unit

1) The higher energy efficiency ratio at the 18°C ​​working condition is as high as 36.86kw/kw, and the energy efficiency ratio of the ordinary screw machine is about 6.0kw/kw;

2) The ordinary screw chiller lubricant maintenance costs 15,000 yuan / year, magnetic levitation units do not need oil maintenance costs;

3) The energy efficiency ratio of the magnetic levitation unit is influenced by the lower temperature of the cooling inlet water. The lower the inlet water temperature is, the higher the energy efficiency ratio is. See the following calculations.

Table 1-2 Lishui Weather Query Form 2014

month

1

2

3

4

5

6

7

8

9

10

11

12

Average temperature (°C)

17.26

18.7

19.42

24.1

26.2

30.1

34.3

33.52

28.4

28.4

24.4

17.1

Table 1-2 Magnetic Suspension Centrifuge Test Data Sheet

No.

Freezing water temperature (°C)

Freezing water temperature (°C)

Cooling water temperature (°C)

Cooling water temperature (°C)

Load kcal*104

Cooling capacity (kw)

Power (kw)

Energy efficiency ratio

Cooling water inlet temperature 20°C

1

20.78

18.92

21.09

24.17

47.2

593.8

38.52

15.42

2

20.82

19.34

20.97

23.49

40.1

469.7

22.67

20.72

3

20.78

19.45

20.95

23.14

37.95

423.97

18.12

23.4

4

20.84

19.67

20.87

22.9

31.9

374.6

14.04

26.69

5

20.76

20.3

20.81

22.03

15.4

233.7

6.34

36.86

Cooling water inlet temperature 25°C

1

22.74

20.67

25.33

28.87

56.8

660.71

53.98

12.24

2

22.36

20.65

25.19

28.26

47.2

549

39.68

13.84

3

21.87

20.41

25

27.54

40.1

466.5

28.07

16.62

4

21.63

20.25

25.31

27.67

37.95

441.5

24.725

17.86

5

21.68

20.51

25.4

27.22

31.9

371.38

17.975

20.66

6

21.11

20.55

25.69

26.66

15.4

179.11

8.075

22.18

Cooling water inlet temperature 30°C

1

22.74

20.39

30.33

34.44

65

750.5

89.91

8.35

2

22.54

20.47

30.56

34.16

55

654.89

71.1

9.21

3

22.04

20.27

30.33

33.49

48.5

565.31

52.11

10.85

4

21.9

20.41

30.29

32.68

41

475.3

37.2

12.78

5

22.24

20.91

30.11

32.13

36.5

424.22

29.8

14.24

6

21.72

20.59

30.34

32.46

31

360.89

25.73

14.03

7

20.95

20.38

30.21

31.22

16

181.91

13.12

13.87

a) In the first group, 1, 2, 3, 4, 11 and 12 months (total 6 months), the ambient temperature is lower than 25°C, and the cooling water inlet temperature is calculated as 20°C.

b) The ambient temperature of the second group of 5, 6, 9 and 10 (for a total of 4 months) is less than 30°C, and the cooling water inlet temperature is calculated at 25°C.

c) The third group of July and August (for a total of 2 months) has an ambient temperature of less than 35°C, and the cooling water inlet temperature is calculated at 30°C.

Rely on the front group to save electricity

name

Cooling capacity (KW)

Power (KW)

Energy Efficiency (COP)

Running time (month)

Running time (h)

Electricity fee (yuan/degree)

Operating expenses (yuan)

Maglev operation costs

374.6

14.04

26.69

6

4320

0.67

$40637.3

Screw unit operating costs

374.6

62.4

6.00

6

4320

0.67

Â¥180610.5

Power-saving cost of magnetic levitation unit = operating cost of magnetic levitation unit - operating cost of screw-type unit

Â¥139973.2

The second group of power-saving calculations

name

Cooling capacity (KW)

Power (KW)

Energy Efficiency (COP)

Running time (month)

Running time (h)

Electricity fee (yuan/degree)

Operating expenses (yuan)

Maglev operation costs

441.5

24.725

17.86

4

2880

0.67

Â¥47709.4

Screw unit operating costs

441.5

73.5

6.00

4

2880

0.67

Â¥141825.6

Power saving cost of magnetic levitation unit = operating cost of magnetic levitation unit - operating cost of screw unit

Â¥94116.2

The third group of power-saving calculations

name

Cooling capacity (KW)

Power (KW)

Energy Efficiency (COP)

Running time (month)

Running time (h)

Electricity fee (yuan/degree)

Operating expenses (yuan)

Maglev operation costs

424.22

29.8

14.24

2

1440

0.67

Â¥28751

Screw unit operating costs

424.22

70.7

6.00

2

1440

0.67

Â¥68214.5

Power saving cost of magnetic levitation unit = operating cost of magnetic levitation unit - operating cost of screw unit

Â¥39463.5

Total annual savings (yuan)

$273552.9

Zhejiang Qingfeng Environment Co., Ltd. Contact: Manager Zhu Address: No. 62 Tongji Street, Shuige Industrial Zone, Lishui City, Zhejiang Province -888

Fax:

Email:

company website:

Cantilever Gate Wheels

Cantilever Gate Wheels ,Heavy Duty Cantilever Gate Rollers,Cantilever Wheels,Cantilever Roller For Sliding Gates

Jiaxing Gates Hardware Products Co.,Ltd , https://www.jxgateshardware.com