Floor House Decoration Precautions Home Decoration Precautions Decoration Precautions House Decoration Precautions Hexagon Thin Nut,M8 Hexagon Nuts,Hexagonal Nuts Fasteners,M39 Hexagonal Nuts Chuangtuo Jinggong (Jiangsu) Co., LTD , https://www.chtofastener.com
[Introduction to anti-static floor]
For the anti-static floor, the anti-static property of the coating should be considered firstly. Secondly, there is the compressive strength, tensile strength and wear resistance, as well as the usual chemical resistance. Therefore, in the formula design, epoxy resin is basically selected as the base material, and conductive materials, fillers, solvents, and additives are added to make antistatic floor coatings.
First, the surface resistance testing 1, inspection equipment preparation: digital megohmmeter, standard electrode.
2. Check the requirements for the environment: Check that the required temperature is between 15 and 31 degrees Celsius, and the humidity is between 45% and 55%.
3, inspection methods: First, clean the ground with gauze, if it encounters particularly serious pollution, it should be cleaned, and then in the use of air-conditioning and other equipment to keep the room temperature for more than two or three days, and then use the electrode table and trillion The positive electrodes of Eurometer are connected, and the negative electrode is connected to the ground. After the application of the voltage, the voltage is applied until the number is stable and then the reading is performed. This must be repeated in a certain range for many times, focusing on measuring the contaminated places.
Second, how to detect static floor parameters
1, detection apparatus: digital megohmmeter, copper standard electrode.
2. Environmental requirements: This environment requires the same humidity and temperature as the surface resistance test environment.
3, inspection methods: This resistance detection method and surface resistance test method.
Third, anti-static floor parameter indicator detection Note humidity and temperature effects on the detection: resistance detection will be increased by temperature and humidity and anti-static resistance value decreases, especially the surface resistance is relatively sensitive to humidity, and volume resistance The sensitivity of temperature is also very large, the increase of temperature will form a water film on the surface of the floor, and the water will enhance the conductivity, which is not conducive to errors in the measurement of the floor parameters.
Xiaobian conclusion: The above introduced the parameters of anti-static floor , I hope to be helpful to everyone. For more relevant knowledge, please continue to pay attention to this website information platform. Follow-up will present more exciting content for everyone.
Precautions for the detection of anti-static floor parameters
The anti-static floor has a dust-proof, static-reducing, antistatic effect lasting, high mechanical strength, and impact resistance. The basic requirements are not high, easy to install, ventilation effect is good, easy to clean, etc., then the composition of the anti-static floor is how? Anti-static flooring parameters how to detect everyone know?