Class I dielectric NPO-CT series radial monolithic capacitor Electric Valve,Electric Solenoid Valve 12V,Electrically Operated Valves,Electric Actuated Ball Valve Haogong Valve Co Ltd , https://www.haogongvalve.com
product description
Http://news.chinawj.com.cn Editor: (Hardware Business Network Information Center) http://news.chinawj.com.cn Class I medium NPO-CT series radial monolithic capacitors---Features and applications, ordering needs, main technical indicators 1. Product Features and Applications: These products are small in size, large in capacity, suitable for automatic installation of rolls (woven) with packaging; epoxy resin packaging, which has excellent moisture resistance, mechanical strength and heat resistance. 1.1, media type Class I medium Class I 1.2, characteristics Electrical performance is the most stable, with little change in temperature, voltage and time 1.3, application Suitable for high-frequency circuits with low loss and high stability requirements, such as filters, vibrators and timing circuits. 2, ordering needs (please specify the following parameters, in order to accurately confirm the specifications and models, other parameters are not specified can be directly contact confirmation 0758-6182388-802) 2.1, dielectric materials NPO(N) 2.2, the temperature range of use: _55°C~+125°C 2.3, electrostatic capacity range: 0.5pF~0.1uF 2.4, capacity tolerance error: J=±5%, K=±10% 2.5, rated voltage (UR): 25VDC, 50VDC, 100VDC, 1000VDC, etc. 2.6, pitch size: 2.54MM, 5.08MM, etc. 2.7, pitch size: 3.5MM~28MM 2.8, packaging method: Bulk packaging, braiding (cassette packaging, roll box packaging) 2.9, environmental standards: ROHS six items, REACH84 items 3. Main technical indicators 3.1, reference standards: GB2693 3.2, capacity test standards: Tested at 1MHZ (C≤1000PF), Vrms=1.0V, 25°C±2°C, the capacity is within the tolerance Tested at 1KHZ (C>1000PF), Vrms=1.0V, 25°C±2°C, the capacity is within the tolerance 3.3, loss angle tangent test standard: Tested at 1MHZ (C≤1000PF), Vrms=1.0V, 25°C±2°C, the loss reaches the specified standard; C≥50PF DF≤0.0015; C<50PF DF≤1.5[(150/CR)+7]×10 -4 Tested at 1KHZ (C>1000PF), Vrms=1.0V, 25°C±2°C, the loss reaches the specified standard; C≥50PF DF≤0.0015 3.4, withstand voltage (Ut) test standards: Ut=3UR (apply 3 times rated voltage for 1-5 seconds (charge and discharge current below 50MA), no abnormality) 3.5. Insulation resistance test standard: Apply a voltage of ±3% of rated voltage. When the charge and discharge current is 50MA, the test time is 60S, IR reaches the specified standard: C≤10NF IR.≥10000MΩ; C>10NF CR≥100Ω×F