Mixing station manufacturers show emergency plan for sudden power failure of concrete mixing plant

Mixing station manufacturers show the concrete mixing station sudden power failure emergency plan concrete mixing station operation process, there will be many emergencies, such as power outage, water cut, leakage, parts damage, etc., here, share the concrete mixing station power failure After the presentation of the problem and the urgent operation process.

After the outbreak of the power outage, the staff should be told agilely that the power outage was caused by the power outage of the external power grid, and the power distribution equipment of the concrete mixing station was still in trouble, and the power failure time was determined agilely. If the power is turned off due to the external power grid, immediately tell the generator set personnel to start the generator set. If the power distribution equipment of the concrete mixing station is in trouble, causing power failure, the power distribution equipment should be repaired immediately. If the downtime will be more than 30 minutes to more than 3 hours, you need to tell the construction site, the pump truck, and the staff, and then supply the goods after the incident is completed.

After the power is cut off, the concrete mixing station staff should promptly handle the production materials in the equipment. After the concrete mixing station is shut down and the power is turned off, the air compressor of the air control system is always in the exhaust condition until the air compressor is started again. The reason for this phenomenon is that the pressure of the air compressor rises slowly. And there is an oil scene, clarifying that the piston ring of the air compressor is now worn and needs to be replaced. If there is no oil sight, you can place the palm of your hand on the air inlet of the air filter. If the hot air comes out, clarify the damage of the intake valve and replace it. If you put your palm on the air-filtered inlet gas, you feel a suction, but the strength is weak. It can be judged that the air filter is blocked by other dust and impurities. It is necessary to clean the filter, and if possible, replace the new filter.

In order to ensure the normal operation of the concrete mixing station and avoid the sudden power outage, the staff is required to regularly check the internal circuit of the mixing station, and regularly maintain and protect the generator set.

For more information on concrete mixing plants | concrete mixers, please consult http://free order hotline 400-963-9100
Http://news.chinawj.com.cn Mixing station manufacturers show emergency plan for sudden power failure of concrete mixing plant Editor: (Hardware Business Network Information Center) http://news.chinawj.com.cn Mixing station manufacturers show emergency plan for sudden power failure of concrete mixing plant