Washing equipment, dryer, ironing machine, folding machine, feeding machine Q: 120kg washing machine can not enter the water, drain, computer controller button action is normal? Paiticle Board,Particle Board Vs Plywood,Particle Board Bunnings,Particle Board Flooring Linyi Fengzhize Trading Co., Ltd. , https://www.fengzhize.com
A: First confirm whether the 24V power supply is normal, check the fuse for damage. Check if the compressed air reaches the rated pressure. Generally it is a pressure of 5 - 7 kg.
Q: Why can't the pumping pump be pumped out after the dry cleaning machine pump is turned on?
Answer: Whether the idling time is long before the liquid pump causes the solvent in the pipeline to be evacuated. Check if the liquid pump seal is in good condition. If the seal is broken, air will not be pumped when it enters the liquid pump. Check that the relevant pneumatic valves are normally open and that the direction of the liquid pump is correct.
Q: When the dryer is running, the radiator is not heated?
A: Confirm if the steam valve is open. Check the trap for blockages, clean and replace.
Q: Fully enclosed dry cleaning machine - high off the shutdown alarm?
A: There are too many sundries or piles in the button trap, which affects the speed of high de-discharge. Confirm that the button trap drain valve is open. The high de-discharging time setting is too short to prolong the high de-discharging time.
Q: Can the water machine start?
Answer: The power is turned on, the phase loss is short, the emergency stop switch is not reset, the gate signal is not activated, the controller is caused, and the drive belt is loose;
Q: Can you wash and add water?
A: Control temperature setting, solenoid valve action, valve opening, compressed air, steam, water source;
Q: Is the inverter overheated?
Answer: ventilation, voltage, heat dissipation motor, bearing;
Q: Is the vibration too large?
Answer: The amount of cloth, water level, uniform distribution, drainage, super-shock switch, shock absorber;
Q: Is the spindle abnormal noise?
Answer: Lack of lubricating oil, loose spindle fastening nut and bearing wear;
Q: Is the door leaking?
Answer: The door is not closed, the seal is damaged, and the door lock device is loose;
Q: The drainage is not smooth?
Answer: The drain port is blocked, the cylinder is faulty, and the solenoid valve is faulty.
Q: Buying equipment, I hope to contact the company to see how to contact?
A: First contact the company's resident office or the company's Ministry of Commerce, and the office or the Ministry of Commerce will forward it to the relevant department of the company's headquarters, and then the company's headquarters staff will contact the customer about the inspection.
Q: When we buy a device that encounters a fault that is more difficult to diagnose, but the device needs to be urgently needed, what is the best way to deal with it?
A: Usually contact the service personnel in the local office first. If the fault cannot be confirmed after going to the door, report it to the company headquarters for research. If necessary, the company will send relevant technical personnel to the customer for troubleshooting and repair, and conduct the customer. Training guidance.
Q: What is the reason why the folding machine does not fold when the fabric is folded?
A: The main questions are as follows:
1. Check if the photoelectric switch has a model number.
2. Check if the speed indicator signal is correct.
3. Check if the blowing solenoid valve is open and the air pressure is adjusted to the working pressure.
Whether the fabric is oversized exceeds the maximum allowable size of the folding machine.
China Hardware Business Network http://news.chinawj.com.cn Editor: (Hardware Business Network Information Center) http://news.chinawj.com.cn