Ultrasonic flowmeters are accurate, reliable, and more suitable for industrial sites. The present invention provides a multifunctional pull faucet, comprising: a faucet body, a drawing part is provided at the water outlet port thereof, and the drawing part is connected to a main channel, wherein at least three are provided in the faucet body A branch channel, and the three branch channels are all connected to the main channel. A multifunctional pull faucet provided by the present invention, wherein the hot water channel, the cold water channel and the water purification channel (pure water channel) are all connected to the main channel , And the main channel is connected with the drawing part on the main body of the faucet, so that the drawing part can obtain the water quality (hot water, cold water, purified water or pure water) required by different users, thereby improving the user experience, and , By integrating the hot water channel, cold water channel and pure water channel (pure water channel) into the main channel, the internal structure of the faucet is simplified, and the production cost of the faucet is reduced. Pull Out Faucets,Pull Out Kitchen Tap,Pull Out Sink Faucet,Standard Pull Out Faucet Yuyao Zelin Sanitary Ware Co., Ltd , https://www.zlsanitaryware.com
Ultrasonic flowmeter installation is the easiest and most convenient way to install all flowmeters. Just select a suitable measuring point, input the large pipe parameters at the measuring point into the flowmeter, and then fix the sensor on the pipe.
In order to ensure the measurement accuracy and stability, the installation point of the sensor should be selected in the straight pipe section with uniform fluid distribution (the pipe must be filled with liquid during installation). The principle must be followed: select the fluid-filled material to be uniform and easy to be ultrasonically transmitted. Pipe section, such as vertical pipe section (fluid upward flow) or horizontal pipe section; installation distance should be selected from upstream more than 10 times straight pipe, downstream more than 5 times straight pipe without any valve elbow, variable diameter and other straight pipe sections, installation point Keep away from interference sources such as valves, pumps, high voltages, and inverters; avoid installation at the highest point of the piping system or vertical piping with free outlets (fluid flow down); for open or half full piping The flowmeter should be installed at the U-shaped pipe section; the temperature and pressure of the installation point should be within the range of the sensor's work; fully consider the fouling of the inner wall of the pipe: try to select the place without scale as the installation point. If it is not met, the scale can be considered as a lining for better measurement accuracy; the two sensors must be installed in the horizontal direction of the pipe shaft surface and installed within ±45° of the horizontal position of the axis to prevent the upper part. There are symptoms such as dissatisfaction of tubes, bubbles or sedimentation in the lower part, which affects the normal measurement of the sensor. If it is not possible to install horizontally opposite the installation space, the sensor can be installed vertically or at an angled angle while ensuring that there is no air bubble in the upper part of the pipe.
Huajiang Automation can provide you with the most professional ultrasonic flowmeter selection recommendations and the most reliable instrument products. If you have any questions, we will have professional technicians to help you with your answers. I hope to bring you help!
Http://news.chinawj.com.cn Editor: (Hardware Business Network Information Center) http://news.chinawj.com.cn