Bias and protection of transformers in inverter arc welding power supply (2)

2 magnetic protection

In order to avoid saturation of the magnetic core of the transformer caused by bias, a sufficient air gap can be added to the magnetic circuit of the transformer to improve the linearity of the magnetic permeability, even when the magnetic density is selected in a one-way working state. However, these measures all affect the improvement of the output power of the transformer, and thus cannot reflect the advantages of high utilization of the transformer of the bridge inverter circuit, and also increase the volume and quality of the transformer. A simple and practical method to prevent biasing is to add a DC blocking capacitor on the primary side of the transformer. The circuit is shown in the figure. The DC component of the transformer is blocked by the isolation of the capacitor.

As shown in FIG. 4, before and after the series blocking capacitors, the positive and negative half cycle volts seconds A1 and A2 shown in FIG. 4b are not equal; FIG. 4b shows the series DC blocking capacitor, since the capacitor C floats the DC level, The positive and negative half cycle volt-second products are balanced, that is, A1=A2.

Straight-line capacitors connected in series should use non-polar film capacitors with high frequency performance. The capacitor and the primary side equivalent inductance form a series resonant circuit, and its resonant frequency fR can be expressed as

In order to avoid deterioration of capacitor performance caused by heat loss, the equivalent resistance should be as small as possible, and multiple parallel connections may be made if necessary. The specific method is to test the temperature rise of the capacitor during operation, generally should be controlled below a few degrees. After the DC blocking capacitor is used, the biasing problem of the transformer can be solved, so that the working magnetic flux density of the transformer can work close to the saturation point like the power frequency 50Hz transformer, so that the transformer output power of the bridge inverter circuit is high and the utilization rate is high. The features are fully utilized. Figure 5 shows the measured capacitor voltage and current waveforms before and after the DC blocking capacitor is set. It can be seen from Fig. 5b that the primary current of the transformer is obviously unbalanced and has a large peak before the DC blocking capacitor is added; Fig. 5b shows the current waveform after the DC blocking capacitor is added, and the positive and negative half cycle waveforms are substantially symmetrical.

The best way to prevent biasing is to design a special automatic balancing circuit that forces the magnetic flux to be balanced. The schematic diagram of this circuit is shown in Figure 6.

The same current transformer is used on the two bridge arms of the full-bridge inverter circuit, and the magnitudes of the two currents are compared. In the working process, as long as the current imbalance is detected, the width of the power switch tube driving pulse is dynamically adjusted to ensure that the working magnetic flux of the transformer can be symmetric about the origin. This kind of circuit is more complicated than the primary side series blocking capacitor of the transformer, and the production cost is correspondingly higher, but its function of correcting the bias is very strong.
3 Conclusion

The transformer bias problem of the full-bridge inverter circuit should be given enough attention in the design process, not only from the control circuit, feedback circuit, drive circuit and power switching device, but also to avoid imbalance and inconsistency, but also according to actual needs. Different anti-biasing techniques are used.

references:

[1] Huang Shisheng, new arc welding power supply and its intelligent control (1st edition) [M]. Beijing: Mechanical Industry Press, 2000.

[2] Li Aiwen, Zhang Chenghui. Modern Inverter Technology and Its Applications (1st Edition) [M] Beijing: Science Press, 2000.

Previous page

Stainless Steel Cooling Rack

Baking rack,baking cooling mesh,Baking cooling rack,Cooling Rack, steel wire cooling rack, etc.

Baking wire mesh is made of high quality 304 stainless steel, never rusting and durable. Cooling Wire mesh does not have any coating or chemical ingredients, making food safer.

Multi-functional Grill Cooking rack: the wire mesh is mainly used for outdoor cooking, it can also be used as a cooling and baking rack. Or you can develop other uses for it.

2 tier Cooling Rack,3 tier Cooling Rack,Foldable Cooling Rack,Creative Cooling Rack

Shenzhen Lanejoy Technology Co.,LTD , https://www.wirefruitbasket.com