Here you can find the related products in Portable Meter, we are professional manufacturer of Portable Meter,Ph Pen Meter,Ph Pen Tester,Pen Type PH Meter Price. We focused on international export product development, production and sales. We have improved quality control processes of Portable Meter to ensure each export qualified product. Portable Meter,Ph Pen Meter,Ph Pen Tester,Pen Type Ph Meter Price Xi'an Gavin Electronic Technology Co., Ltd , https://www.gaimc-meas.com
If you want to know more about the products in Portable Meter, please click the product details to view parameters, models, pictures, prices and other information about Portable Meter,Ph Pen Meter,Ph Pen Tester,Pen Type Ph Meter Price.
Whatever you are a group or individual, we will do our best to provide you with accurate and comprehensive message about Portable Meter!
Centrifugal pump regulation and energy consumption introduction
Centrifugal pump and piping system through the characteristic curve diagram of the centrifugal pump flow control of several major ways: the outlet valve regulation, pump speed regulation and pump series, parallel regulation. The energy consumption loss of the outlet valve and the pump speed regulation are analyzed by the characteristic curve diagram. The comparison shows that the flow rate of the centrifugal pump is better than that of the outlet valve to regulate the flow rate, and the energy saving efficiency And the size of traffic changes. In the practical application should pay attention to the scope of variable speed adjustment, in order to better use centrifugal pump speed adjustment. Centrifugal pumps are a versatile fluid machinery widely used in chemical industrial systems. It has a wide range of performance to adapt to (including flow, pressure head and the nature of the transport medium adaptability), small size, simple structure, easy operation, low operating costs and many other advantages. Usually, the selected centrifugal pump flow, head pressure may be inconsistent with the requirements of the pipeline, or due to production tasks, process requirements change, this time require the pump flow control, in essence, to change the operating point of the centrifugal pump. Centrifugal pump operating point is determined by the pump characteristic curve and piping system characteristic curve, therefore, to change any of the characteristic curve can achieve the purpose of flow adjustment. At present, the centrifugal pump flow control methods are the main control valve, variable speed control and the pump and the series adjustment. Due to the different principles of various adjustment methods, in addition to their own advantages and disadvantages, the resulting energy loss is not the same, in order to find the best, minimum energy consumption, the most energy-efficient flow regulation, you must fully understand the centrifugal pump flow adjustment The relationship between mode and energy consumption. 1. The main method of pump flow regulation 1.1 to change the pipeline characteristic curve The most simple method to change the centrifugal pump flow is to use the outlet of the pump outlet valve to control, its essence is to change the position of the pipeline characteristic curve to change the pump work point. 1.2 Change the centrifugal pump characteristics curve According to the law of proportion and cutting law, change the pump speed, change the pump structure (such as cutting impeller diameter method, etc.) can change the centrifugal pump characteristics of the two curves, so as to adjust the flow (at the same time Change the pressure head) purposes. However, for already working pumps, the method of changing the pump structure is less convenient and the versatility of the pump is reduced by changing the pump structure, although it is economically convenient at some times to regulate the flow1 and is rarely used in production . Here only analyze the change of centrifugal pump speed regulation method. When the pump speed is changed to adjust the flow rate from Q1 to Q2, the pump speed (or motor speed) drops from n1 to n2, and the pump speed is n2, the characteristic curve of pump QH and the pipeline characteristic curve He = H0 + G1Qe2 Curve does not change) to point A3 (Q2, H3), A3 is the new operating point after adjusting the flow through the speed. The adjustment method has the advantages of obvious regulation effect, quickness, safety and reliability, prolonging the service life of the pump and saving electric energy, and additionally reducing the rotational speed operation can effectively reduce the NPSHr of the centrifugal pump and keep the pump away from the cavitation zone and reduce the centrifugal pump The possibility of cavitation occurs 2. The disadvantage is the need to change the pump speed through the variable frequency technology to change the prime mover (usually the motor) speed, the principle of complex, large investment, and the flow adjustment range. 1.3 pump string, and even adjust the way When a single centrifugal pump can not meet the delivery tasks, you can use the centrifugal pump in parallel or series operation. In parallel with two centrifugal pumps of the same type, although the pressure head changes little, but increases the total delivery flow, the total efficiency of the parallel pump is the same with the efficiency of a single pump; when the centrifugal pump is connected in series, the total pressure head increases, Little change in flow, the total efficiency of tandem pumps with a single pump the same efficiency. 2. Analysis of Energy Consumption of Pumps under Different Regulation Modes In the analysis of energy consumption under different regulation modes, the article only analyzes the two adjustment methods widely used in valve regulation and pump variable speed regulation. As the centrifugal pump and the tandem operation aims to improve the pressure head or flow in the chemical industry is not much use of its energy consumption can be combined with Figure 2 analysis, the method is basically the same. 2.1 When the valve to adjust the flow of power consumption Centrifugal pump operation, the motor input shaft power N is: N = vQH / η Where N - shaft power, w; Q - pump effective pressure head, m; H - the actual pump flow, m3 / s; v - fluid specific gravity, N / m3; η - pump efficiency. When the valve is used to regulate the flow rate from Q1 to Q2, the shaft power consumed at the operating point A2 is: NA2 = vQ2H2 / η vQ2H3 - Actual useful power, W; vQ2 (H2-H3) vQ2H2 (1 / η-1) - centrifugal pump loss of power, W. 2.2 variable speed flow control power consumption in the analysis of variable speed centrifugal pump due to the need to use the law of proportion, according to its application conditions, the following analysis refers to the centrifugal pump speed range of ± 20%, and the centrifugal pump itself efficiency Little change 3. When the motor is used to regulate the flow rate to the flow rate Q2, the shaft power consumed by the pump at the working point A3 is: NA3 = vQ2H3 / η The same can be obtained by transforming NA3 = vQ2H3 + vQ2H3 (1 / η- 1) Actual useful power, W; vQ2H3 (1 / η-1) - Centrifugal pump loss of power, W. 2.3 Comparison of energy consumption 3. Conclusions For the current centrifugal pump outlet valve regulation and pump speed control two main flow adjustment methods, pump variable speed control of energy saving than the outlet valve regulation much larger, which can From both the power analysis and power comparison analysis shows. Through the centrifugal pump flow and lift diagram, you can more intuitively reflect the energy consumption of the two adjustment mode. Reducing the flow through pump speed regulation also helps to reduce the possibility of cavitation in the centrifugal pump. When the flow rate decreases, the energy-saving efficiency of variable speed regulation is greater, that is, the greater the power loss of valve regulation, however, the pump efficiency is too large when the pump speed is too large, which is beyond the scope of the pump law of proportion. Therefore, Should consider from many aspects, in between the two out of the best flow control methods.